THE PLUMB GUARD APP

Plumb Guard MKIII and newer units are equipped with built-in Bluetooth connectivity, allowing you to pair your device directly with the Plumb Guard V3 App. Once connected, your mobile device will display real-time alerts alongside the on-unit warnings—ensuring you never miss a voltage alarm on-site.

The app is free to download and use, giving every Plumb Guard user a simple and convenient way to stay connected to their device. For those who need enhanced reporting or job traceability, optional premium features are available, including data logging, email alerts, and secure cloud storage.*

Stay informed. Stay protected. Work smarter with Plumb Guard.

*Additional subscription services available.

calibration & Repairs

Keep your Plumb Guard accurate and operating reliably with professional calibration and repair services.

All Plumb Guard devices are calibrated before dispatch and supplied with a calibration certificate and verification sticker. Each calibration is valid for 12 months from the date of calibration.

Before use, confirm your unit is within its valid calibration period by checking:

  • The calibration sticker on the top-left corner of the lid, or

  • The calibration certificate supplied with your unit.

If your calibration has expired, return your unit for recalibration before further use.

If your Plumb Guard is damaged, fails its lead test or is not operating correctly, book it for assessment and repair. Please include a description of the issue when completing the form.

To arrange either service, click “Book Repairs & Calibration” below and complete the form. Once submitted, send your Plumb Guard to us for the required assessment, repairs and/or recalibration.

Recalibrated units are returned with an updated calibration certificate and verification sticker.

Keep your Plumb Guard ready. Keep your team safe.

test & tag

Shunt cables (also known as bridging cables or bonding leads) are used for temporary electrical bonding to safely manage stray or induced voltage on water assets before, during, and after repair works. To ensure these critical safety devices remain reliable, they should be tested every 12 months to verify continuity and load-bearing capability.

When tested by the Plumb Guard Team, each cable undergoes a comprehensive inspection, including:

  • Verification of clean and secure connection points

  • Visual check for damage or deterioration

  • Continuity testing to confirm electrical integrity

  • Load testing to 200 amps to confirm the cable core remains structurally sound and capable of carrying fault current

This testing ensures your bonding leads remain safe, effective, and compliant for field use as part of your electrical safety controls.

In addition to annual verification, shunt/bridging cables should be inspected monthly by trained personnel to confirm both the continuity and physical condition of the cable are suitable for ongoing use.

Please note: Cables that connect directly to your Plumb Guard Unit do not require this monthly continuity test, as the Plumb Guard performs a continuity check each time the TEST function is successfully completed.

To arrange your cables to be Tested & Tagged, simply click the “Book Test & Tag” button below and complete the form.